Description
Parker VMY315K10N1P Proportional Reducing Valve
Function VMY*K06:
With the proportional solenoids de-energized, the main spring forces the main spool into the neutral position. Port A is connected to port T. Thus the reduced pressure only depends on the back pressure in the external drain pipe and/or the tank pressure and can accordingly be reduced down to 0 bar. The pressure present in the P line delivers the pilot oil to the pilot stage via a flow control valve.
When the proportional solenoid is energized, the pilot pressure is increased in the pilot pressure area, and the main spool moves against the spring until the connection P – A opens. The regulation of the reduced pressure on connection A takes place by the constant comparison of the actual pressure and the reference pressure of the pilot stage.
Function VMY*K10:
The valve spool is designed so that the connection B-A is open in the neutral position and is closed in the working position.
Pilot Inlet / Drain Locations:
315 bar
Port Connection:
NG10 / CETOP 05
Actuation Type:
Proportional
Seal Material:
NBR
Product Series:
Pressure valve
Maximum Operating Pressure:
350 bar
Minimum Operating Temperature:
-20 °C
Flow Rate:
160 L/min
Body Material:
Steel
Mounting Type:
Subplate mounting
Operation Type:
Pilot
Pressure Control Range:
Internal / internal
Weight:
5 kg
Maximum Flow Rate:
N/A
Maximum Operating Temperature:
60 °C
Seal Material:
NBR
Maximum Pressure Setting:
315 bar