Description
1. General Overview
Parker SCFT-150-22-07 Turbine Flow Meter
The Parker SCFT-150-22-07 is a high-performance flow meter belonging to the High Pressure Connectors Europe Division. Designed for mobile and industrial hydraulics,
it offers accurate flow measurement with several advanced features, making it an ideal choice for systems dealing with oil-based hydraulic fluids.
2. Technical Specifications
Calibration Type: None
Operating Pressure: 350 bar, capable of handling high-pressure hydraulic systems.
Port Type: BSPP (British Standard Pipe Parallel), ensuring secure and standardized connections.
Product Style: Turbine, utilizing a turbine wheel mechanism for flow measurement.
Port Size: G3/4 BSPP, a common and widely used port size for compatibility.
Flow Rates: Operates within a range of 5…150 l/min, with the ability to cover 6 measuring ranges of up to 750 l/min, providing flexibility for different applications.
Product Type: Flow meter
Operating Temperature: -10…+50 °C
Maximum Fluid Temperature: 80 °C
Minimum Fluid Temperature: -20 °C, allowing operation in a relatively wide temperature range.
Specifications Met: CE, meeting European safety and performance standards.
For Fluid Type: Suitable for oil-based hydraulic fluids, making it applicable to many hydraulic systems.
Weight: 1600 g
Height: 130 mm
Length: 190 mm
Width: 62 mm
Accuracy: ± 1 % IR, ensuring precise flow measurement.
Additional Function: Enables flow measurement with low flow resistance.
It also allows for combined p (pressure), T (temperature), and Q (flow) measurement when additional sensors are used.
3. Function
The Parker SCFT-150-22-07 operates by using a turbine wheel that is driven by the oil flow.
The frequencies generated as a result of the turbine’s rotation are processed by digital electronics. The design of the flow meter effectively compensates for the influence of turbulent flow effects.
Due to its low flow resistance (QR), the hydraulic circuit experiences very low losses during operation.
For pressure measurement, the turbine is equipped with an EMA-3 quick-connector. Additionally, oil temperatures can be measured directly within the oil flow inside the turbine flow meter.
This means that all the crucial measurement parameters are accessible at a single measuring location, streamlining the measurement process.
4. Features and Advantages
Multiple Measuring Ranges: Offers 6 measuring ranges of up to 750 l/min, providing versatility to meet the diverse flow measurement needs of different hydraulic systems.
Easy Installation: Its design allows for straightforward installation, reducing the time and effort required for setup.
High-Pressure Resistance: Can withstand pressures up to 480 bar, ensuring reliable operation even in high-pressure environments.
Low Flow Resistance: Minimizes the losses in the hydraulic circuit, improving the overall efficiency of the system.
Built-in Measurement Connections: Comes with built-in pressure and temperature measurement connections, enabling comprehensive monitoring of important parameters without the need for complex additional installations.
Suitable for Reverse-Mode Operation: It is capable of operating in reverse mode, adding to its flexibility and usability in various hydraulic applications.
5. Application Markets
The Parker SCFT-150-22-07 is mainly targeted at the mobile and industrial hydraulics markets.
It can be used in a wide range of applications such as construction machinery, agricultural equipment, and industrial manufacturing systems where accurate flow, pressure, and temperature measurement of oil-based hydraulic fluids is essential.
In summary, the Parker SCFT-150-22-07 flow meter combines accuracy, durability, and flexibility, making it a reliable choice for hydraulic systems in mobile and industrial settings.